{"id":162,"date":"2026-03-31T15:24:07","date_gmt":"2026-03-31T06:24:07","guid":{"rendered":"https:\/\/www.san-eielectric.co.jp\/am\/?page_id=162"},"modified":"2026-04-28T12:03:36","modified_gmt":"2026-04-28T03:03:36","slug":"summary","status":"publish","type":"page","link":"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/summary\/","title":{"rendered":"Summary"},"content":{"rendered":"\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-large-font-size wp-elements-d782b4363bde4c8c88657fd1a5bccb30\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">1. Purpose of Measurement<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The purpose of this test is to verify the reproducibility and stability of irradiance when illumination is restarted after the shutter of a solar simulator has been closed.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">In practical use, the shutter is frequently closed during operations such as sample replacement or measurement preparation. Therefore, it is important to understand how quickly the irradiance stabilizes after the shutter is reopened, and whether the duration of shutter closure affects the irradiance level.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">In this test, the time-dependent irradiance behavior was measured under different shutter-closure durations in order to evaluate whether the length of shutter closure influences the irradiance behavior after illumination is resumed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-large-font-size wp-elements-05a8703f377eeec945ccc8eb3d745fe3\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">2. Overall Evaluation of the Measurement Results<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The irradiance behavior after reopening the shutter was compared under two shutter-closure conditions: 1 minute and 1 hour.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The results show that the irradiance rise behavior is almost identical under both conditions. In both cases, the irradiance is already stable immediately after the shutter is opened, and only a slight upward trend is observed over time.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"535\" src=\"https:\/\/www.san-eielectric.co.jp\/am\/wp-content\/uploads\/2026\/03\/image02.jpg\" alt=\"\" class=\"wp-image-163\"\/><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">This behavior is considered to be caused by the temperature characteristics of the pyranometer, as previously confirmed in <a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/\" data-type=\"page\" data-id=\"160\">the 24-hour continuous illumination test<\/a>. Therefore, the observed change does not indicate a change in the irradiance of the light source itself.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">No significant differences were observed in the irradiance level or recovery behavior between the two shutter-closure durations.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Based on these results, it can be concluded that the duration of shutter closure does not have a significant effect on the reproducibility or stability of irradiance after the shutter is reopened.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Furthermore, even when the shutter-closure duration was varied from 1 minute to 1 hour, no difference in irradiance behavior was observed. This indicates that changes in the thermal state of the optical system caused by shutter operation have a negligible effect on irradiance reproducibility.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">These results also indicate that stable irradiation conditions are reproduced even after routine operational procedures such as sample replacement. From the perspective of operational reproducibility, this behavior represents a favorable characteristic of the solar simulator.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">For more detailed discussion of this behavior, please refer to the measurement results of <a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/\" data-type=\"page\" data-id=\"160\"><strong>the 24-hour continuous illumination test.<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-large-font-size wp-elements-0280f056a1fffe060d54bd8055ac32d2\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">Observations<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">For the models measured so far, the irradiance observed in the 6H measurements remains within a limited range around the average value, and no significant temporal variation has been observed during the measurement period.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">In contrast, the 24H continuous measurements show a gradual change in irradiance together with the increase in pyranometer temperature.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The results obtained from the Main and Sub pyranometers show generally similar trends, indicating that the observed behavior reflects the characteristics of the measurement system rather than a malfunction of an individual sensor.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Note:<br>Please refer to the individual model pages for detailed measurement conditions and results for each solar simulator model.<\/p>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Model<\/strong><\/td><td><strong>Effective Irradiation Area<\/strong><\/td><td><strong>Link<\/strong><\/td><\/tr><tr><td>XES-20S1<\/td><td>20 \u00d7 20 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/shutter-recovery-test-xes-20s1\/\" data-type=\"page\" data-id=\"404\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-40S3<\/td><td>40 \u00d7 40 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/shutter-recovery-test-xes-40s3\/\" data-type=\"page\" data-id=\"436\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-50S2<\/td><td>50 \u00d7 50 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/shutter-recovery-test-xes-50s2\/\" data-type=\"page\" data-id=\"439\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-50S3<\/td><td>50 \u00d7 50 mm<\/td><td>MeasurShutter Recovery Testement results page<\/td><\/tr><tr><td>XES-70S1<\/td><td>70 \u00d7 70 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/shutter-recovery-test-xes-70s1\/\" data-type=\"page\" data-id=\"442\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-100S1<\/td><td>100 \u00d7 100 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/shutter-recovery-test-xes-100s1\/\" data-type=\"page\" data-id=\"445\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-160S1<\/td><td>160 \u00d7 160 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/xes-160s1\/\" data-type=\"page\" data-id=\"168\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-200S1<\/td><td>200 \u00d7 200 mm<\/td><td>MeasurShutter Recovery Testement results page<\/td><\/tr><tr><td>XES-250S1<\/td><td>250 \u00d7 250 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/xes-250s1\/\" data-type=\"page\" data-id=\"171\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-300S1<\/td><td>300 \u00d7 300 mm<\/td><td><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/xes-300s1\/\" data-type=\"page\" data-id=\"178\">MeasurShutter Recovery Testement results page<\/a><\/td><\/tr><tr><td>XES-300S2<\/td><td>300 \u00d7 300 mm<\/td><td>MeasurShutter Recovery Testement results page<\/td><\/tr><tr><td>XES-300S3<\/td><td>300 \u00d7 300 mm<\/td><td>MeasurShutter Recovery Testement results page<\/td><\/tr><tr><td>XES-400S1<\/td><td>400 \u00d7 400 mm<\/td><td>MeasurShutter Recovery Testement results page<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/shutter-recovery-test\/\" data-type=\"page\" data-id=\"160\">Return to INDEX<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>1. Purpose of Measurement The purpose of this test is to verify the reproducibility and stability of irradianc [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":160,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-162","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/comments?post=162"}],"version-history":[{"count":7,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/162\/revisions"}],"predecessor-version":[{"id":1011,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/162\/revisions\/1011"}],"up":[{"embeddable":true,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/160"}],"wp:attachment":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/media?parent=162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}