{"id":147,"date":"2026-03-21T12:18:58","date_gmt":"2026-03-21T03:18:58","guid":{"rendered":"https:\/\/www.san-eielectric.co.jp\/am\/?page_id=147"},"modified":"2026-04-26T17:54:22","modified_gmt":"2026-04-26T08:54:22","slug":"irradiance-stability-test-24h-6h","status":"publish","type":"page","link":"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/","title":{"rendered":"Irradiance Stability Test (24H \/ 6H)"},"content":{"rendered":"\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-155d5985 wp-block-group-is-layout-constrained\" style=\"border-width:1px;margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<h2 class=\"wp-block-heading has-large-font-size\"><strong>INDEX<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-grid wp-container-core-group-is-layout-7b2a5a25 wp-block-group-is-layout-grid\" style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\">\n<p class=\"has-medium-font-size wp-container-content-574e1f9d wp-block-paragraph\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/summary\/\">Summary<\/a><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-container-content-574e1f9d wp-block-paragraph\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/measurement-procedure\/\">Measurement Method for Long-Term Irradiance Stability(24-Hour Continuous Illumination)<\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-large-font-size wp-elements-904fcb3307d264f4110355827e084e68\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">Long-Term Irradiance Stability under 24-Hour Continuous Irradiation<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">This page presents the results of irradiance stability measurements conducted under 24-hour continuous irradiation using SAN-EI single-lamp Solar Simulators.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-contrast-color has-text-color has-link-color has-large-font-size wp-elements-18f246b786c3e1fe9d86b53514f0c417\" style=\"border-width:1px;padding-top:5px;padding-right:var(--wp--preset--spacing--20);padding-bottom:5px;padding-left:var(--wp--preset--spacing--20)\">24-hour measurement (24H measurement)<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>The purpose of this measurement<\/strong> is to visualize the variation characteristics of the reference irradiance (1 SUN) during long-term operation and to quantitatively show the fluctuation range and temporal variation behavior.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color wp-elements-c6f7f1d7ffb790e54cfd4fb1cc64f66b\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">The measurement<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>The measurement<\/strong> is evaluated using the following two tests in order to observe the long-term behavior of irradiance and to confirm the influence of the irradiance sensor temperature.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-contrast-color has-text-color has-link-color wp-elements-ade88e45b4719cc0e9b5ace7077a4ef6\" style=\"border-width:1px;padding-top:5px;padding-right:var(--wp--preset--spacing--20);padding-bottom:5px;padding-left:var(--wp--preset--spacing--20)\">24-hour measurement (24H measurement)<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">This measurement evaluates the temporal variation characteristics of irradiance during 24 hours of continuous irradiation and assesses the fluctuation range and long-term drift during extended operation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-contrast-color has-text-color has-link-color wp-elements-8562bc8a46deda7d22b3884bd429febe\" style=\"border-width:1px;padding-top:5px;padding-right:var(--wp--preset--spacing--20);padding-bottom:5px;padding-left:var(--wp--preset--spacing--20)\">6-hour measurement (6H measurement)<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">This measurement observes the irradiance behavior after system start-up and evaluates the relationship between pyranometer temperature and surrounding temperature.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-large-font-size wp-elements-17f57122d49f793e3ef278669de59153\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">Measurement Concept<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">In long-duration irradiance measurements, the measured value can change not only due to the light source but also due to the temperature characteristics of the irradiance sensor.<br>Therefore, this measurement distinguishes between the stability of the light source and the influence of the sensor temperature.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">A 24-hour continuous irradiation test is conducted to observe the long-term behavior of irradiance.<br>In parallel, a 6-hour measurement with intermittent exposure of the sensor is performed to confirm the influence of sensor temperature rise.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">To evaluate operational stability, the stability time is defined as the time when irradiance first enters the \u00b11% band of the average irradiance of a visually determined stable region and does not leave this band thereafter.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">All statistical values are calculated using the data within this stable region.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The measurement results for each model are published as individual pages.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-contrast-color has-text-color has-link-color wp-elements-f85930232a0f9ea968fd4dc0ef98a9da\" style=\"border-width:1px;padding-top:5px;padding-right:var(--wp--preset--spacing--20);padding-bottom:5px;padding-left:var(--wp--preset--spacing--20)\">Target Models<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Small size<\/strong><\/h4>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">20\u00d720\uff0d50\u00d750 mm<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-20s1\/\" data-type=\"page\" data-id=\"453\">XES-20S1<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-40s3\/\" data-type=\"page\" data-id=\"468\">XES-40S3<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-50s2\/\" data-type=\"page\" data-id=\"498\">XES-50S2<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-50s3\/\">XES-50S3<\/a><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Medium size<\/strong><\/h4>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">70\u00d770\uff0d200\u00d7200 mm<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-70s1\/\" data-type=\"page\" data-id=\"515\">XES-70S1<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-100s1\/\" data-type=\"page\" data-id=\"530\">XES-100S1<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-160s1\/\" data-type=\"page\" data-id=\"546\">XES-160S1<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-200s1\/\" data-type=\"page\" data-id=\"695\">XES-200S1<\/a><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Large size<\/strong><\/h4>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">250\u00d7250\uff0d400\u00d7400 mm<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-250s1\/\" data-type=\"page\" data-id=\"563\">XES-250S1<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-300s1\/\" data-type=\"page\" data-id=\"578\">XES-300S1<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\">XES-300S2<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/irradiance-stability-test-xes-300s3\/\" data-type=\"page\" data-id=\"714\">XES-300S3<\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\">XES-400S1<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-504e767964d83868ed01ec35553489ae\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">Each model page<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\">Warm-up time<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Average irradiance<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Maximum value<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Minimum value<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Variation range<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Temporal variation rate<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Long-term drift<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Comparison of main and sub pyranometers<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Relationship between irradiance and temperature<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading has-base-color has-contrast-background-color has-text-color has-background has-link-color has-large-font-size wp-elements-6259ce9d5ca1c431399a80355b03ce54\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">Related pages<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/measurement-procedure\/\" data-type=\"page\" data-id=\"157\"><strong>Measurement Method<\/strong><\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/measurement-reports-index\/irradiance-stability-test-24h-6h\/summary\/\" data-type=\"page\" data-id=\"148\"><strong>Summary Page<\/strong><\/a><\/li>\n\n\n\n<li class=\"has-medium-font-size\"><a href=\"https:\/\/www.san-eielectric.co.jp\/am\/en\/contact\/\" data-type=\"page\" data-id=\"29\"><strong>Contact<\/strong><\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>INDEX Summary Measurement Method for Long-Term Irradiance Stability(24-Hour Continuous Illumination) Long-Term [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":143,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-147","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/comments?post=147"}],"version-history":[{"count":7,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/147\/revisions"}],"predecessor-version":[{"id":828,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/147\/revisions\/828"}],"up":[{"embeddable":true,"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/pages\/143"}],"wp:attachment":[{"href":"https:\/\/www.san-eielectric.co.jp\/am\/wp-json\/wp\/v2\/media?parent=147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}